{"product_id":"deanta-lorient-acoustic-smoke-fire-seal","title":"Deanta Lorient Acoustic, Smoke, \u0026 Fire Seal","description":"\u003cp data-end=\"376\" data-start=\"24\"\u003eThe \u003cstrong data-end=\"74\" data-start=\"28\"\u003eDeanta Lorient Acoustic, Smoke \u0026amp; Fire Seal\u003c\/strong\u003e is a high-performance internal door seal designed to provide reliable protection against \u003cstrong data-end=\"190\" data-start=\"164\"\u003esound, smoke, and fire\u003c\/strong\u003e. Ideal for use with fire-rated doors, this seal expands when exposed to heat, effectively closing gaps between the door and frame to help prevent the spread of flames, smoke, and noise.\u003c\/p\u003e\n\u003cp data-end=\"832\" data-start=\"378\"\u003eManufactured using \u003cstrong data-end=\"459\" data-start=\"397\"\u003ePVC-encased sodium silicate with flexible elastomeric fins\u003c\/strong\u003e, this seal delivers excellent acoustic performance while remaining durable and long-lasting. Suitable for both \u003cstrong data-end=\"603\" data-start=\"571\"\u003esingle and double-leaf doors\u003c\/strong\u003e, it meets key UK fire and smoke safety standards, making it a dependable choice for residential and commercial fire door installations. Supplied in a discreet black finish, it integrates seamlessly with Deanta fire door systems.\u003c\/p\u003e\n\u003ch2 data-end=\"865\" data-start=\"839\"\u003eTechnical Specification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-end=\"915\" data-start=\"869\"\u003eBrand: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eDeanta Doors\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"976\" data-start=\"918\"\u003eSeal Manufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eLorient\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1027\" data-start=\"979\"\u003eProduct Type: Acoustic, Smoke \u0026amp; Fire Door Seal\u003c\/li\u003e\n\u003cli data-end=\"1046\" data-start=\"1030\"\u003eLength: 2100mm\u003c\/li\u003e\n\u003cli data-end=\"1070\" data-start=\"1049\"\u003eWidth (Depth): 15mm\u003c\/li\u003e\n\u003cli data-end=\"1089\" data-start=\"1073\"\u003eThickness: 4mm\u003c\/li\u003e\n\u003cli data-end=\"1107\" data-start=\"1092\"\u003eColour: Black\u003c\/li\u003e\n\u003cli data-end=\"1171\" data-start=\"1110\"\u003eMaterial: PVC-encased sodium silicate with elastomeric fins\u003c\/li\u003e\n\u003cli data-end=\"1203\" data-start=\"1174\"\u003eApplication: Internal doors\u003c\/li\u003e\n\u003cli data-end=\"1245\" data-start=\"1206\"\u003eDoor Type: Single \u0026amp; double-leaf doors\u003c\/li\u003e\n\u003cli data-end=\"1278\" data-start=\"1248\"\u003eDurability: 1 million cycles\u003c\/li\u003e\n\u003cli data-end=\"1315\" data-start=\"1281\"\u003eProtections: Sound, Smoke \u0026amp; Fire\u003c\/li\u003e\n\u003cli data-end=\"1347\" data-start=\"1318\"\u003eAvailability: Web Exclusive\u003c\/li\u003e\n\u003cli data-end=\"1381\" data-start=\"1349\"\u003e\n\u003cstrong data-end=\"1381\" data-start=\"1349\"\u003ePerformance \u0026amp; Certification:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli data-end=\"1418\" data-start=\"1384\"\u003eAcoustic: BS EN ISO 10140-2:2010\u003c\/li\u003e\n\u003cli data-end=\"1446\" data-start=\"1421\"\u003eSmoke: BS 476-31.1:1983\u003c\/li\u003e\n\u003cli data-end=\"1491\" data-start=\"1449\"\u003eFire: BS EN 1634-1:2008 \u0026amp; BS 476-22:1987\u003c\/li\u003e\n\u003cli data-end=\"1526\" data-start=\"1494\"\u003eSmoke Compliance: BS 9999:2017\u003c\/li\u003e\n\u003cli data-end=\"1569\" data-start=\"1529\"\u003eCertification: Certifire CF330 \u0026amp; CF341\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1583\" data-start=\"1576\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-end=\"1752\" data-start=\"1585\"\u003e\u003cstrong data-end=\"1625\" data-start=\"1585\"\u003eWhat does this seal protect against?\u003c\/strong\u003e\u003cbr data-end=\"1628\" data-start=\"1625\"\u003eIt provides protection against sound transmission, smoke leakage, and fire spread when used as part of a tested door system.\u003c\/p\u003e\n\u003cp data-end=\"1907\" data-start=\"1754\"\u003e\u003cstrong data-end=\"1790\" data-start=\"1754\"\u003eIs this suitable for fire doors?\u003c\/strong\u003e\u003cbr data-end=\"1793\" data-start=\"1790\"\u003eYes, it is designed specifically for use with fire-rated doors and meets relevant fire and smoke safety standards.\u003c\/p\u003e\n\u003cp data-end=\"2019\" data-start=\"1909\"\u003e\u003cstrong data-end=\"1944\" data-start=\"1909\"\u003eCan it be used on double doors?\u003c\/strong\u003e\u003cbr data-end=\"1947\" data-start=\"1944\"\u003eYes, it is suitable for both single and double-leaf door configurations.\u003c\/p\u003e\n\u003cp data-end=\"2191\" data-start=\"2021\"\u003e\u003cstrong data-end=\"2058\" data-start=\"2021\"\u003eHow does the seal work in a fire?\u003c\/strong\u003e\u003cbr data-end=\"2061\" data-start=\"2058\"\u003eWhen exposed to heat, the intumescent material expands to seal gaps between the door and frame, helping to block flames and smoke.\u003c\/p\u003e\n\u003cp data-end=\"2309\" data-start=\"2193\"\u003e\u003cstrong data-end=\"2235\" data-start=\"2193\"\u003eWill this work with Deanta fire doors?\u003c\/strong\u003e\u003cbr data-end=\"2238\" data-start=\"2235\"\u003eYes, it is fully compatible with Deanta fire doors and sealing systems.\u003c\/p\u003e","brand":"Deanta","offers":[{"title":"Default Title","offer_id":56592585687415,"sku":"LP1504DS","price":3.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0444\/8675\/4460\/files\/M700-2024-11-14--8-13-3-289.jpg?v=1769116476","url":"https:\/\/www.tradesuperstoreonline.co.uk\/products\/deanta-lorient-acoustic-smoke-fire-seal","provider":"Trade Superstore Online","version":"1.0","type":"link"}