{"product_id":"manual-callpoint-red-isolator-for-xp95","title":"Manual Callpoint Red + Isolator for XP95","description":"\u003cp data-start=\"112\" data-end=\"932\"\u003eThe XP95 Red Manual Call Point with Isolator is a high-performance addressable device designed for fast, reliable fire alarm activation in commercial and industrial environments. Featuring a \u003cstrong data-start=\"402\" data-end=\"430\"\u003eseven-segment DIL switch\u003c\/strong\u003e for easy address configuration at commissioning, this unit offers rapid alarm reporting in under \u003cstrong data-start=\"528\" data-end=\"543\"\u003e0.2 seconds\u003c\/strong\u003e, making it ideal for mission-critical systems. Its bi-coloured LED indicators clearly show normal, fault, and activated states, ensuring quick identification of call point status. Fully certified to \u003cstrong data-start=\"743\" data-end=\"755\"\u003eEN 54-11\u003c\/strong\u003e and \u003cstrong data-start=\"760\" data-end=\"772\"\u003eEN 54-17\u003c\/strong\u003e, this manual call point is suited for use in medium to large-scale applications such as offices, data centres, healthcare facilities, and government buildings.\u003c\/p\u003e\n\u003ch2 data-start=\"934\" data-end=\"963\"\u003e\u003cstrong data-start=\"934\" data-end=\"961\"\u003eTechnical Specification\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"964\" data-end=\"1633\"\u003e\n\u003cli data-start=\"964\" data-end=\"1029\"\u003e\n\u003cp class=\"m1393376886287170430xmsolistparagraph\" style=\"margin: 0cm; background: white;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos',sans-serif; mso-bidi-font-family: Arial; color: #222222;\"\u003eDownload Product Technical \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0444\/8675\/4460\/files\/datasheet_2500445449_01.pdf?v=1753868068\" target=\"_blank\" rel=\"noopener\"\u003eData Sheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan lang=\"EN-GB\" style=\"font-size: 11.0pt; font-family: 'Aptos',sans-serif; mso-bidi-font-family: Arial; color: #222222; mso-ansi-language: EN-GB;\"\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"964\" data-end=\"1029\"\u003e\n\u003cp data-start=\"966\" data-end=\"1029\"\u003e\u003cstrong data-start=\"966\" data-end=\"982\"\u003eProduct Type\u003c\/strong\u003e: Addressable Manual Call Point with Isolator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1030\" data-end=\"1073\"\u003e\n\u003cp data-start=\"1032\" data-end=\"1073\"\u003e\u003cstrong data-start=\"1032\" data-end=\"1049\"\u003eCompatibility\u003c\/strong\u003e: Apollo XP95 protocol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1074\" data-end=\"1136\"\u003e\n\u003cp data-start=\"1076\" data-end=\"1136\"\u003e\u003cstrong data-start=\"1076\" data-end=\"1090\"\u003eAddressing\u003c\/strong\u003e: 7-segment DIL switch for manual addressing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1137\" data-end=\"1293\"\u003e\n\u003cp data-start=\"1139\" data-end=\"1160\"\u003e\u003cstrong data-start=\"1139\" data-end=\"1157\"\u003eLED Indicators\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"1163\" data-end=\"1293\"\u003e\n\u003cli data-start=\"1163\" data-end=\"1196\"\u003e\n\u003cp data-start=\"1165\" data-end=\"1196\"\u003e\u003cstrong data-start=\"1165\" data-end=\"1172\"\u003eRed\u003c\/strong\u003e: Call point activated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1199\" data-end=\"1236\"\u003e\n\u003cp data-start=\"1201\" data-end=\"1236\"\u003e\u003cstrong data-start=\"1201\" data-end=\"1217\"\u003eAmber\/Yellow\u003c\/strong\u003e: Fault condition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1239\" data-end=\"1293\"\u003e\n\u003cp data-start=\"1241\" data-end=\"1293\"\u003e\u003cstrong data-start=\"1241\" data-end=\"1254\"\u003eBi-colour\u003c\/strong\u003e: Indicates isolate and normal states\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1294\" data-end=\"1355\"\u003e\n\u003cp data-start=\"1296\" data-end=\"1355\"\u003e\u003cstrong data-start=\"1296\" data-end=\"1313\"\u003eResponse Time\u003c\/strong\u003e: Reports alarm in less than 0.2 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1356\" data-end=\"1456\"\u003e\n\u003cp data-start=\"1358\" data-end=\"1379\"\u003e\u003cstrong data-start=\"1358\" data-end=\"1376\"\u003eCertifications\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"1382\" data-end=\"1456\"\u003e\n\u003cli data-start=\"1382\" data-end=\"1415\"\u003e\n\u003cp data-start=\"1384\" data-end=\"1415\"\u003eEN 54-11 (Manual Call Points)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1418\" data-end=\"1456\"\u003e\n\u003cp data-start=\"1420\" data-end=\"1456\"\u003eEN 54-17 (Short Circuit Isolators)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1457\" data-end=\"1633\"\u003e\n\u003cp data-start=\"1459\" data-end=\"1478\"\u003e\u003cstrong data-start=\"1459\" data-end=\"1475\"\u003eApplications\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"1481\" data-end=\"1633\"\u003e\n\u003cli data-start=\"1481\" data-end=\"1505\"\u003e\n\u003cp data-start=\"1483\" data-end=\"1505\"\u003eCommercial buildings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1508\" data-end=\"1528\"\u003e\n\u003cp data-start=\"1510\" data-end=\"1528\"\u003eIndustrial sites\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1531\" data-end=\"1557\"\u003e\n\u003cp data-start=\"1533\" data-end=\"1557\"\u003eFinancial institutions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1560\" data-end=\"1585\"\u003e\n\u003cp data-start=\"1562\" data-end=\"1585\"\u003eGovernment facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1588\" data-end=\"1603\"\u003e\n\u003cp data-start=\"1590\" data-end=\"1603\"\u003eIT\/Telecoms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1606\" data-end=\"1633\"\u003e\n\u003cp data-start=\"1608\" data-end=\"1633\"\u003eHealthcare environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1635\" data-end=\"1812\"\u003e\u003cstrong data-start=\"1635\" data-end=\"1694\"\u003eEnsure rapid fire detection and enhanced system control\u003c\/strong\u003e with the XP95 Manual Call Point with Isolator — engineered for performance, reliability, and full system integration.\u003c\/p\u003e","brand":"Trade Superstore Online","offers":[{"title":"Default Title","offer_id":55512180982135,"sku":"55100-908APO","price":41.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0444\/8675\/4460\/files\/product_2500445449_01.webp?v=1753868127","url":"https:\/\/www.tradesuperstoreonline.co.uk\/products\/manual-callpoint-red-isolator-for-xp95","provider":"Trade Superstore Online","version":"1.0","type":"link"}