{"product_id":"twinflex-pro-2-zone-panel","title":"Twinflex Pro 2 Zone Panel","description":"\u003cp data-start=\"231\" data-end=\"770\"\u003eThe \u003cstrong data-start=\"235\" data-end=\"264\"\u003eTwinflex Pro 2 Zone Panel\u003c\/strong\u003e is an advanced, intelligent \u003cstrong data-start=\"293\" data-end=\"328\"\u003e2-wire fire alarm control panel\u003c\/strong\u003e designed to simplify installation while delivering high-performance fire detection. Ideal for smaller premises such as offices, shops, or small commercial buildings, this panel supports up to \u003cstrong data-start=\"521\" data-end=\"556\"\u003e32 Twinflex devices per circuit\u003c\/strong\u003e, allowing \u003cstrong data-start=\"567\" data-end=\"629\"\u003esmoke detectors, heat detectors, call points, and sounders\u003c\/strong\u003e to be connected on the same pair of wires. This drastically reduces cabling, labour, and installation costs compared to traditional systems.\u003c\/p\u003e\n\u003cp data-start=\"772\" data-end=\"1137\"\u003eThe Twinflex Pro is capable of \u003cstrong data-start=\"803\" data-end=\"851\"\u003eautomatically identifying the type of device\u003c\/strong\u003e triggering the alarm—be it smoke, heat, or manual call point—and includes full fault monitoring, programmable inputs\/outputs, and a reliable integrated power supply. For streamlined, cost-effective fire protection without compromising performance, the Twinflex Pro is the ideal choice.\u003c\/p\u003e\n\u003ch2 data-start=\"1139\" data-end=\"1168\"\u003e\u003cstrong data-start=\"1139\" data-end=\"1168\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1170\" data-end=\"2411\"\u003e\n\u003cli data-start=\"1170\" data-end=\"1392\"\u003e\n\u003cp class=\"m1393376886287170430xmsolistparagraph\" style=\"margin: 0cm; background: white;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos',sans-serif; mso-bidi-font-family: Arial; color: #222222;\"\u003eDownload Product Technical \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0444\/8675\/4460\/files\/datasheet_2501141975_01.pdf?v=1754413329\" target=\"_blank\" rel=\"noopener\"\u003eData Sheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan lang=\"EN-GB\" style=\"font-size: 11.0pt; font-family: 'Aptos',sans-serif; mso-bidi-font-family: Arial; color: #222222; mso-ansi-language: EN-GB;\"\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1170\" data-end=\"1392\"\u003e\n\u003cp data-start=\"1172\" data-end=\"1205\"\u003e\u003cstrong data-start=\"1172\" data-end=\"1203\"\u003ePanel Type \u0026amp; Configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1208\" data-end=\"1392\"\u003e\n\u003cli data-start=\"1208\" data-end=\"1265\"\u003e\n\u003cp data-start=\"1210\" data-end=\"1265\"\u003e\u003cstrong data-start=\"1210\" data-end=\"1238\"\u003eAnalogue non-addressable\u003c\/strong\u003e 2-wire fire alarm system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1268\" data-end=\"1337\"\u003e\n\u003cp data-start=\"1270\" data-end=\"1337\"\u003e\u003cstrong data-start=\"1270\" data-end=\"1286\"\u003e2-zone panel\u003c\/strong\u003e, expandable with 4 and 8 zone variants available\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1340\" data-end=\"1392\"\u003e\n\u003cp data-start=\"1342\" data-end=\"1392\"\u003eSupports up to \u003cstrong data-start=\"1357\" data-end=\"1392\"\u003e32 Twinflex devices per circuit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1394\" data-end=\"1640\"\u003e\n\u003cp data-start=\"1396\" data-end=\"1438\"\u003e\u003cstrong data-start=\"1396\" data-end=\"1436\"\u003eDevice Compatibility \u0026amp; Installation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1441\" data-end=\"1640\"\u003e\n\u003cli data-start=\"1441\" data-end=\"1536\"\u003e\n\u003cp data-start=\"1443\" data-end=\"1536\"\u003eAllows \u003cstrong data-start=\"1450\" data-end=\"1500\"\u003eall devices (detectors, call points, sounders)\u003c\/strong\u003e to be installed on the same cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1539\" data-end=\"1592\"\u003e\n\u003cp data-start=\"1541\" data-end=\"1592\"\u003eCompatible with a \u003cstrong data-start=\"1559\" data-end=\"1590\"\u003erange of Twinflex detectors\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1595\" data-end=\"1640\"\u003e\n\u003cp data-start=\"1597\" data-end=\"1640\"\u003eReduces installation time and cabling costs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1642\" data-end=\"1927\"\u003e\n\u003cp data-start=\"1644\" data-end=\"1679\"\u003e\u003cstrong data-start=\"1644\" data-end=\"1677\"\u003eDetection \u0026amp; Fault Monitoring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1682\" data-end=\"1927\"\u003e\n\u003cli data-start=\"1682\" data-end=\"1768\"\u003e\n\u003cp data-start=\"1684\" data-end=\"1768\"\u003eRecognises and distinguishes between \u003cstrong data-start=\"1721\" data-end=\"1766\"\u003esmoke, heat, and manual call point alarms\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1771\" data-end=\"1927\"\u003e\n\u003cp data-start=\"1773\" data-end=\"1800\"\u003eZone monitoring includes:\u003c\/p\u003e\n\u003cul data-start=\"1805\" data-end=\"1927\"\u003e\n\u003cli data-start=\"1805\" data-end=\"1834\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1834\"\u003e\u003cstrong data-start=\"1807\" data-end=\"1832\"\u003eDetector head removal\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1839\" data-end=\"1859\"\u003e\n\u003cp data-start=\"1841\" data-end=\"1859\"\u003e\u003cstrong data-start=\"1841\" data-end=\"1857\"\u003eDevice fault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1864\" data-end=\"1889\"\u003e\n\u003cp data-start=\"1866\" data-end=\"1889\"\u003e\u003cstrong data-start=\"1866\" data-end=\"1887\"\u003eEnd-of-line fault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1894\" data-end=\"1927\"\u003e\n\u003cp data-start=\"1896\" data-end=\"1927\"\u003e\u003cstrong data-start=\"1896\" data-end=\"1927\"\u003eOpen or short circuit fault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1929\" data-end=\"2226\"\u003e\n\u003cp data-start=\"1931\" data-end=\"1954\"\u003e\u003cstrong data-start=\"1931\" data-end=\"1952\"\u003eInputs \u0026amp; Outputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1957\" data-end=\"2226\"\u003e\n\u003cli data-start=\"1957\" data-end=\"2032\"\u003e\n\u003cp data-start=\"1959\" data-end=\"2032\"\u003e\u003cstrong data-start=\"1959\" data-end=\"1982\"\u003e2 monitored outputs\u003c\/strong\u003e (configurable as conventional sounder circuits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2035\" data-end=\"2097\"\u003e\n\u003cp data-start=\"2037\" data-end=\"2097\"\u003e\u003cstrong data-start=\"2037\" data-end=\"2068\"\u003eVolt-free common fire relay\u003c\/strong\u003e and \u003cstrong data-start=\"2073\" data-end=\"2095\"\u003ecommon fault relay\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2100\" data-end=\"2152\"\u003e\n\u003cp data-start=\"2102\" data-end=\"2152\"\u003e\u003cstrong data-start=\"2102\" data-end=\"2150\"\u003e2 multifunction latching\/non-latching inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2155\" data-end=\"2226\"\u003e\n\u003cp data-start=\"2157\" data-end=\"2226\"\u003e\u003cstrong data-start=\"2157\" data-end=\"2191\"\u003e1 programmable monitored input\u003c\/strong\u003e (e.g. Class-Change or Remote Fire)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2228\" data-end=\"2411\"\u003e\n\u003cp data-start=\"2230\" data-end=\"2258\"\u003e\u003cstrong data-start=\"2230\" data-end=\"2256\"\u003ePower Supply \u0026amp; Backup:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2261\" data-end=\"2411\"\u003e\n\u003cli data-start=\"2261\" data-end=\"2304\"\u003e\n\u003cp data-start=\"2263\" data-end=\"2304\"\u003eBuilt-in \u003cstrong data-start=\"2272\" data-end=\"2302\"\u003eintegral power supply unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2307\" data-end=\"2362\"\u003e\n\u003cp data-start=\"2309\" data-end=\"2362\"\u003eRequires \u003cstrong data-start=\"2318\" data-end=\"2345\"\u003e2 x 12V 3.2Ah batteries\u003c\/strong\u003e (not included)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2365\" data-end=\"2411\"\u003e\n\u003cp data-start=\"2367\" data-end=\"2411\"\u003eProvides \u003cstrong data-start=\"2376\" data-end=\"2411\"\u003eup to 72 hours of standby power\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2413\" data-end=\"2604\"\u003eThe \u003cstrong data-start=\"2417\" data-end=\"2446\"\u003eTwinflex Pro 2 Zone Panel\u003c\/strong\u003e delivers intelligent fire detection in a cost-effective, easy-to-install package—perfect for small buildings that require reliable, scalable fire protection.\u003c\/p\u003e","brand":"Trade Superstore Online","offers":[{"title":"Default Title","offer_id":55555013542263,"sku":"505-0002","price":415.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0444\/8675\/4460\/files\/product_2501141975_01_1.webp?v=1754413411","url":"https:\/\/www.tradesuperstoreonline.co.uk\/products\/twinflex-pro-2-zone-panel","provider":"Trade Superstore Online","version":"1.0","type":"link"}