{"product_id":"twinflex-pro-4-zone-panel","title":"Twinflex Pro 4 Zone Panel","description":"\u003cp data-start=\"229\" data-end=\"872\"\u003eThe \u003cstrong data-start=\"233\" data-end=\"262\"\u003eTwinflex Pro 4 Zone Panel\u003c\/strong\u003e is a cutting-edge, intelligent \u003cstrong data-start=\"294\" data-end=\"329\"\u003e2-wire fire alarm control panel\u003c\/strong\u003e, designed for simplicity, reliability, and flexibility in small to medium-sized buildings. Supporting up to \u003cstrong data-start=\"438\" data-end=\"470\"\u003e32 Twinflex devices per zone\u003c\/strong\u003e, this analogue non-addressable panel streamlines installation by allowing detectors, call points, and sounders to be installed on the same cable. Perfect for schools, offices, retail spaces, and other commercial environments, the Twinflex Pro automatically distinguishes between \u003cstrong data-start=\"750\" data-end=\"769\"\u003esmoke detectors\u003c\/strong\u003e, \u003cstrong data-start=\"771\" data-end=\"789\"\u003eheat detectors\u003c\/strong\u003e, and \u003cstrong data-start=\"795\" data-end=\"817\"\u003emanual call points\u003c\/strong\u003e, reducing false alarms and increasing system accuracy.\u003c\/p\u003e\n\u003cp data-start=\"874\" data-end=\"1058\"\u003eEquipped with fault monitoring, flexible inputs\/outputs, and an integral power supply, the Twinflex Pro 4 Zone is a robust fire safety solution that meets modern building safety needs.\u003c\/p\u003e\n\u003ch2 data-start=\"1060\" data-end=\"1089\"\u003e\u003cstrong data-start=\"1060\" data-end=\"1089\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1091\" data-end=\"2217\"\u003e\n\u003cli data-start=\"1091\" data-end=\"1240\"\u003e\n\u003cp class=\"m1393376886287170430xmsolistparagraph\" style=\"margin: 0cm; background: white;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos',sans-serif; mso-bidi-font-family: Arial; color: #222222;\"\u003eDownload Product Technical \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0444\/8675\/4460\/files\/datasheet_2501141976_01.pdf?v=1754410454\" target=\"_blank\" rel=\"noopener\"\u003eData Sheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan lang=\"EN-GB\" style=\"font-size: 11.0pt; font-family: 'Aptos',sans-serif; mso-bidi-font-family: Arial; color: #222222; mso-ansi-language: EN-GB;\"\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1091\" data-end=\"1240\"\u003e\n\u003cp data-start=\"1093\" data-end=\"1110\"\u003e\u003cstrong data-start=\"1093\" data-end=\"1108\"\u003ePanel Type:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1113\" data-end=\"1240\"\u003e\n\u003cli data-start=\"1113\" data-end=\"1141\"\u003e\n\u003cp data-start=\"1115\" data-end=\"1141\"\u003eAnalogue non-addressable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1144\" data-end=\"1180\"\u003e\n\u003cp data-start=\"1146\" data-end=\"1180\"\u003eIntelligent 2-wire configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1183\" data-end=\"1240\"\u003e\n\u003cp data-start=\"1185\" data-end=\"1240\"\u003e\u003cstrong data-start=\"1185\" data-end=\"1196\"\u003e4 zones\u003c\/strong\u003e, supporting \u003cstrong data-start=\"1209\" data-end=\"1238\"\u003eup to 32 devices per zone\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1242\" data-end=\"1481\"\u003e\n\u003cp data-start=\"1244\" data-end=\"1280\"\u003e\u003cstrong data-start=\"1244\" data-end=\"1278\"\u003eInstallation \u0026amp; Device Support:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1283\" data-end=\"1481\"\u003e\n\u003cli data-start=\"1283\" data-end=\"1337\"\u003e\n\u003cp data-start=\"1285\" data-end=\"1337\"\u003eSupports up to \u003cstrong data-start=\"1300\" data-end=\"1335\"\u003e32 Twinflex devices per circuit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1340\" data-end=\"1425\"\u003e\n\u003cp data-start=\"1342\" data-end=\"1425\"\u003eAll devices (detectors, sounders, call points) can be installed on the same cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1428\" data-end=\"1481\"\u003e\n\u003cp data-start=\"1430\" data-end=\"1481\"\u003eSimplifies installation and reduces cabling costs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1483\" data-end=\"1750\"\u003e\n\u003cp data-start=\"1485\" data-end=\"1520\"\u003e\u003cstrong data-start=\"1485\" data-end=\"1518\"\u003eMonitoring \u0026amp; Fault Detection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1523\" data-end=\"1750\"\u003e\n\u003cli data-start=\"1523\" data-end=\"1607\"\u003e\n\u003cp data-start=\"1525\" data-end=\"1607\"\u003eAutomatically identifies smoke detectors, heat detectors, and manual call points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1610\" data-end=\"1750\"\u003e\n\u003cp data-start=\"1612\" data-end=\"1637\"\u003eMonitors each zone for:\u003c\/p\u003e\n\u003cul data-start=\"1642\" data-end=\"1750\"\u003e\n\u003cli data-start=\"1642\" data-end=\"1667\"\u003e\n\u003cp data-start=\"1644\" data-end=\"1667\"\u003eDetector head removal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1672\" data-end=\"1688\"\u003e\n\u003cp data-start=\"1674\" data-end=\"1688\"\u003eDevice fault\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1693\" data-end=\"1714\"\u003e\n\u003cp data-start=\"1695\" data-end=\"1714\"\u003eEnd-of-line fault\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1719\" data-end=\"1750\"\u003e\n\u003cp data-start=\"1721\" data-end=\"1750\"\u003eOpen or short circuit fault\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1752\" data-end=\"2029\"\u003e\n\u003cp data-start=\"1754\" data-end=\"1777\"\u003e\u003cstrong data-start=\"1754\" data-end=\"1775\"\u003eInputs \u0026amp; Outputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1780\" data-end=\"2029\"\u003e\n\u003cli data-start=\"1780\" data-end=\"1851\"\u003e\n\u003cp data-start=\"1782\" data-end=\"1851\"\u003e2 monitored outputs (configurable as conventional sounder circuits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1854\" data-end=\"1908\"\u003e\n\u003cp data-start=\"1856\" data-end=\"1908\"\u003eVolt-free common fire relay and common fault relay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1911\" data-end=\"1959\"\u003e\n\u003cp data-start=\"1913\" data-end=\"1959\"\u003e2 multifunction latching\/non-latching inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1962\" data-end=\"2029\"\u003e\n\u003cp data-start=\"1964\" data-end=\"2029\"\u003e1 programmable monitored input (e.g. Class-Change, Remote Fire)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2031\" data-end=\"2217\"\u003e\n\u003cp data-start=\"2033\" data-end=\"2069\"\u003e\u003cstrong data-start=\"2033\" data-end=\"2067\"\u003ePower Supply \u0026amp; Battery Backup:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2072\" data-end=\"2217\"\u003e\n\u003cli data-start=\"2072\" data-end=\"2115\"\u003e\n\u003cp data-start=\"2074\" data-end=\"2115\"\u003eIncludes \u003cstrong data-start=\"2083\" data-end=\"2113\"\u003eintegral power supply unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2118\" data-end=\"2173\"\u003e\n\u003cp data-start=\"2120\" data-end=\"2173\"\u003eRequires \u003cstrong data-start=\"2129\" data-end=\"2156\"\u003e2 x 12V 3.2Ah batteries\u003c\/strong\u003e (not included)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2176\" data-end=\"2217\"\u003e\n\u003cp data-start=\"2178\" data-end=\"2217\"\u003eProvides \u003cstrong data-start=\"2187\" data-end=\"2217\"\u003eup to 72-hour standby time\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2219\" data-end=\"2411\"\u003eThe \u003cstrong data-start=\"2223\" data-end=\"2252\"\u003eTwinflex Pro 4 Zone Panel\u003c\/strong\u003e delivers an ideal mix of intelligent detection, simplified wiring, and reliable performance—making it a top choice for professional fire safety installations.\u003c\/p\u003e","brand":"Trade Superstore Online","offers":[{"title":"Default Title","offer_id":55554804253047,"sku":"505-0004","price":499.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0444\/8675\/4460\/files\/product_2501141976_01.webp?v=1754410511","url":"https:\/\/www.tradesuperstoreonline.co.uk\/products\/twinflex-pro-4-zone-panel","provider":"Trade Superstore Online","version":"1.0","type":"link"}