{"product_id":"twinflex-pro-8-zone-panel","title":"Twinflex Pro 8 Zone Panel","description":"\u003cp data-start=\"233\" data-end=\"774\"\u003eThe \u003cstrong data-start=\"237\" data-end=\"277\"\u003eTwinflex Pro 8 Zone Fire Alarm Panel\u003c\/strong\u003e is a high-performance, intelligent \u003cstrong data-start=\"313\" data-end=\"348\"\u003e2-wire fire alarm control panel\u003c\/strong\u003e designed for medium to large installations. As part of the trusted Twinflex range, this panel supports up to \u003cstrong data-start=\"458\" data-end=\"490\"\u003e32 Twinflex devices per zone\u003c\/strong\u003e, allowing \u003cstrong data-start=\"501\" data-end=\"605\"\u003esmoke detectors, heat detectors, call points, and sounders to be installed on the same pair of wires\u003c\/strong\u003e—greatly reducing installation time and costs. The \u003cstrong data-start=\"656\" data-end=\"674\"\u003e8-zone variant\u003c\/strong\u003e is ideal for complex building layouts and is controlled via a secure key switch for added security.\u003c\/p\u003e\n\u003cp data-start=\"776\" data-end=\"992\"\u003eEngineered for reliability, the Twinflex Pro features advanced fault monitoring, configurable outputs, and integrated power supply, making it a powerful solution for schools, offices, retail, and industrial premises.\u003c\/p\u003e\n\u003ch2 data-start=\"994\" data-end=\"1023\"\u003e\u003cstrong data-start=\"994\" data-end=\"1023\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1025\" data-end=\"2167\"\u003e\n\u003cli data-start=\"1025\" data-end=\"1277\"\u003e\n\u003cp class=\"m1393376886287170430xmsolistparagraph\" style=\"margin: 0cm; background: white;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt; font-family: 'Aptos',sans-serif; mso-bidi-font-family: Arial; color: #222222;\"\u003eDownload Product Technical \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0444\/8675\/4460\/files\/datasheet_2501141977_01.pdf?v=1754411630\" target=\"_blank\" rel=\"noopener\"\u003eData Sheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan lang=\"EN-GB\" style=\"font-size: 11.0pt; font-family: 'Aptos',sans-serif; mso-bidi-font-family: Arial; color: #222222; mso-ansi-language: EN-GB;\"\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1025\" data-end=\"1277\"\u003e\n\u003cp data-start=\"1027\" data-end=\"1055\"\u003e\u003cstrong data-start=\"1027\" data-end=\"1053\"\u003ePanel Type \u0026amp; Capacity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1058\" data-end=\"1277\"\u003e\n\u003cli data-start=\"1058\" data-end=\"1116\"\u003e\n\u003cp data-start=\"1060\" data-end=\"1116\"\u003eIntelligent \u003cstrong data-start=\"1072\" data-end=\"1100\"\u003eanalogue non-addressable\u003c\/strong\u003e 2-wire system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1119\" data-end=\"1149\"\u003e\n\u003cp data-start=\"1121\" data-end=\"1149\"\u003eSupports \u003cstrong data-start=\"1130\" data-end=\"1147\"\u003eup to 8 zones\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1152\" data-end=\"1191\"\u003e\n\u003cp data-start=\"1154\" data-end=\"1191\"\u003e\u003cstrong data-start=\"1154\" data-end=\"1189\"\u003e32 Twinflex devices per circuit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1194\" data-end=\"1277\"\u003e\n\u003cp data-start=\"1196\" data-end=\"1277\"\u003e\u003cstrong data-start=\"1196\" data-end=\"1237\"\u003eAll devices share a single cable pair\u003c\/strong\u003e (no need for separate sounder circuits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1279\" data-end=\"1551\"\u003e\n\u003cp data-start=\"1281\" data-end=\"1310\"\u003e\u003cstrong data-start=\"1281\" data-end=\"1308\"\u003eDetection \u0026amp; Monitoring:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1313\" data-end=\"1551\"\u003e\n\u003cli data-start=\"1313\" data-end=\"1409\"\u003e\n\u003cp data-start=\"1315\" data-end=\"1409\"\u003eAutomatically recognises \u003cstrong data-start=\"1340\" data-end=\"1359\"\u003esmoke detectors\u003c\/strong\u003e, \u003cstrong data-start=\"1361\" data-end=\"1379\"\u003eheat detectors\u003c\/strong\u003e, and \u003cstrong data-start=\"1385\" data-end=\"1407\"\u003emanual call points\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1412\" data-end=\"1551\"\u003e\n\u003cp data-start=\"1414\" data-end=\"1439\"\u003eMonitors each zone for:\u003c\/p\u003e\n\u003cul data-start=\"1444\" data-end=\"1551\"\u003e\n\u003cli data-start=\"1444\" data-end=\"1469\"\u003e\n\u003cp data-start=\"1446\" data-end=\"1469\"\u003eDetector head removal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1474\" data-end=\"1490\"\u003e\n\u003cp data-start=\"1476\" data-end=\"1490\"\u003eDevice fault\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1495\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1497\" data-end=\"1516\"\u003eEnd-of-line fault\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1521\" data-end=\"1551\"\u003e\n\u003cp data-start=\"1523\" data-end=\"1551\"\u003eOpen or short circuit faults\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1553\" data-end=\"1866\"\u003e\n\u003cp data-start=\"1555\" data-end=\"1578\"\u003e\u003cstrong data-start=\"1555\" data-end=\"1576\"\u003eInputs \u0026amp; Outputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1581\" data-end=\"1866\"\u003e\n\u003cli data-start=\"1581\" data-end=\"1656\"\u003e\n\u003cp data-start=\"1583\" data-end=\"1656\"\u003e\u003cstrong data-start=\"1583\" data-end=\"1606\"\u003e2 monitored outputs\u003c\/strong\u003e (configurable as conventional sounder circuits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1659\" data-end=\"1696\"\u003e\n\u003cp data-start=\"1661\" data-end=\"1696\"\u003e\u003cstrong data-start=\"1661\" data-end=\"1694\"\u003e1 volt-free common fire relay\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1699\" data-end=\"1737\"\u003e\n\u003cp data-start=\"1701\" data-end=\"1737\"\u003e\u003cstrong data-start=\"1701\" data-end=\"1735\"\u003e1 volt-free common fault relay\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1740\" data-end=\"1792\"\u003e\n\u003cp data-start=\"1742\" data-end=\"1792\"\u003e\u003cstrong data-start=\"1742\" data-end=\"1790\"\u003e2 multifunction latching\/non-latching inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1795\" data-end=\"1866\"\u003e\n\u003cp data-start=\"1797\" data-end=\"1866\"\u003e\u003cstrong data-start=\"1797\" data-end=\"1831\"\u003e1 programmable monitored input\u003c\/strong\u003e (e.g. Class-Change or Remote Fire)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1868\" data-end=\"2051\"\u003e\n\u003cp data-start=\"1870\" data-end=\"1898\"\u003e\u003cstrong data-start=\"1870\" data-end=\"1896\"\u003ePower Supply \u0026amp; Backup:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1901\" data-end=\"2051\"\u003e\n\u003cli data-start=\"1901\" data-end=\"1944\"\u003e\n\u003cp data-start=\"1903\" data-end=\"1944\"\u003eIncludes \u003cstrong data-start=\"1912\" data-end=\"1942\"\u003eintegral power supply unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1947\" data-end=\"2002\"\u003e\n\u003cp data-start=\"1949\" data-end=\"2002\"\u003eRequires \u003cstrong data-start=\"1958\" data-end=\"1985\"\u003e2 x 12V 3.2Ah batteries\u003c\/strong\u003e (not included)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2005\" data-end=\"2051\"\u003e\n\u003cp data-start=\"2007\" data-end=\"2051\"\u003eProvides \u003cstrong data-start=\"2016\" data-end=\"2051\"\u003eup to 72 hours standby capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2167\"\u003e\n\u003cp data-start=\"2055\" data-end=\"2083\"\u003e\u003cstrong data-start=\"2055\" data-end=\"2081\"\u003eControl \u0026amp; User Access:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2086\" data-end=\"2167\"\u003e\n\u003cli data-start=\"2086\" data-end=\"2167\"\u003e\n\u003cp data-start=\"2088\" data-end=\"2167\"\u003e\u003cstrong data-start=\"2088\" data-end=\"2131\"\u003e8-zone panel controlled by a key switch\u003c\/strong\u003e for secure access and configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2169\" data-end=\"2389\"\u003eThe \u003cstrong data-start=\"2173\" data-end=\"2202\"\u003eTwinflex Pro 8 Zone Panel\u003c\/strong\u003e offers a smart, efficient fire detection system for larger installations, combining ease of installation with advanced functionality—making it a top choice for fire safety professionals.\u003c\/p\u003e","brand":"Trade Superstore Online","offers":[{"title":"Default Title","offer_id":55554892759415,"sku":"505-0008","price":642.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0444\/8675\/4460\/files\/product_2501141977_01_1.webp?v=1754411705","url":"https:\/\/www.tradesuperstoreonline.co.uk\/products\/twinflex-pro-8-zone-panel","provider":"Trade Superstore Online","version":"1.0","type":"link"}